Basic Info
  • Model NO.: PFCC203
  • Type: Insulation Tape
  • Material: Cotton Cloth
  • Maximum Voltage: <10KV
  • Certification: IEC60893-3-4:2003
  • Brand: Toyo
  • Trademark: Toyo
  • Origin: China
  • Application: Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell
  • Chemistry: Organic Insulation
  • Thermal Rating: E
  • Classification: Organic Insulating Material
  • Color: Yellow
  • Specility: Thickness Is Around 1.0~4.5mm
  • Transport Package: Wooden Case
Product Description
Packaging & Delivery
Packaging Details: Standard Package: Wooden cases; We can also pack it according to the customers' requirements.
Delivery Detail:3-7 days
Specifications
thickness is around 1.0~4.5mm
Product Description
Temperature classification is E. Mechanical applications (greige linen). Good mechanical property and lower electrical property.
Technical Data Sheet
Table 1: Nominal thickness, dimension and tolerance
Thickness
mm
Tolerance
mm
Thickness
mm
Tolerance
mm
Thickness
mm
Tolerance
mm
1.0
±0.15
5.0
±0.48
14.0
±1.00
1.2
±0.18
5.5
±0.48
16.0
±1.30
1.5
±0.18
6.0
±0.58
20.0
±1.30
1.8
±0.23
6.5
±0.58
25.0
±1.50
2.0
±0.23
7.0
±0.68
30.0
±1.50
2.5
±0.33
8.0
±0.68
35.0
±2.00
3.0
±0.33
9.0
±0.80
40.0
±2.00
4.0
±0.38
10.0
±0.80
45.0
±2.80
4.5
±0.38
12.0
±1.00
50.0
±2.80
Note: 1. The tolerance mentioned above is only used to refer and the actual one is according to the standard.
     2. Normal dimension: (960±15)mm×(1460±15)mm or negotiated.
 
Table 2: The technical requirements
No
Property
Unit
Normal value
1
Flexural strength perpendicular to layer direction
MPa
≥110
2
Impact strength parallel to the layer direction (Charpy method)
kJ/m2
≥7.0
3
Electrical strength perpendicular to the layer direction at 90±2ºC transformer oil
MV/m
Refer to table 3
4
Breakdown voltage parallel to the layer direction at 90±2ºC transformer oil
kV
≥1
5
Insulation resistance after immersing in water
≥1
6
Water absorption
mg
Refer to table 4
 
Table 3: Electrical strength perpendicular to the layer direction
Thickness
 mm
Normal value
 
Thickness
mm
Normal value
0.5
≥0.98
1.8
≥0.69
0.6
≥0.95
2.0
≥0.65
0.7
≥0.92
2.2
≥0.61
0.8
≥0.89
2.4
≥0.58
0.9
≥0.84
2.6
≥0.56
1.0
≥0.82
2.8
≥0.53
1.2
≥0.80
3.0
≥0.50
1.5
≥0.74
 
 
Note:
1. Electric strength perpendicular to layer direction at 90±2ºC oil can optional choose one 20s raising voltage class by class and the requirement of voltage resistance test for 1 min. If the material is conform with one of the both methods, the electric strength shall be considered to be also conform with the standard.
2. If the arithmetic average of the sample thickness is between the both thicknesses listed in the above table, its requirement value shall use the interpolation method to get. If the average is below 0.4mm,the requirement value of electric strength shall use the one of 0.4mm, If the normal thickness is 3mm and the average of the sample thickness is over 3mm,the requirement value of 3mm shall be used.
 
Table 4: Water absorption
Mean thickness
mm
Max. water absorption
mg
 
Mean thickness
mm
Max. water absorption
mg
0.5
190
5.0
275
0.6
194
6.0
284
0.8
201
8.0
301
1.0
206
10.0
319
1.2
211
12.0
336
1.5
218
14.0
354
2.0
229
16.0
371
2.5
239
20.0
406
3.0
249
25.0
450
4.0
262
Processed by one side to 22.5
540
Note: 1. If the arithmetic average of the sample thickness is between the both thicknesses listed in the above table, its requirement value shall use the interpolation method to get.
   2. If the average is below 0.4mm, the requirement value of water absorption shall use the one of 0.4mm. If the normal thickness is 25mm and the average of the sample's thickness is over 25mm,the requirement value of 25 mm shall be used. If the thickness of the laminates is 25,it shall be processed to 22.5±0.3mm by one-side frame and the surface shall be smooth.
 Packaging & Shipping
Normally the out - packaging for the goods is wooden pallet or wooden case, we can deliver it by air or by ship.
Airport: Beijing, Tianjin, Qingdao, Nanjing, Shanghai, Guangzhou, Shenzhen
Sea Port: Tianjin,Qingdao, Shanghai, Ningbo, Guangzhou
Packing Type Photo is as the following:
Pfcc203 Phenolic Cotton Cloth Laminated SheetPfcc203 Phenolic Cotton Cloth Laminated Sheet
Send your message to this supplier
Avatar
Mr. Robin Zhang
*From:
To: Mr. Robin Zhang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now